When the glue pot temperature drifts, edgebanding quality follows: poor adhesion, stringing, or charred glue. A failed PT100 7150/E sensor leaves the controller without a valid temperature signal, so the machine may not reach setpoint or may fault out. Replacing the sensor restores temperature feedback to the glue pot control loop.
The part is a PT100 resistance thermometer, model PT100 7150/E, with part number 4-008-40-0054 or 4008400054. The sensing element is platinum. It is a temperature sensor for Homag edgebanding machine glue pot accessories. Confirm fit by matching both part numbers and the PT100 7150/E model against the sensor being replaced.
Check the sensor mounting thread and probe length against the old unit before installation. The -50 to 700 range covers the glue pot operating window. A correct seat in the glue pot gives the controller a stable signal, so heat-up and holding are consistent from shift to shift.
Supply is straightforward: SHUNHONGYU supplies various woodworking machine parts, and you can contact us for current availability. Send the part number 4-008-40-0054, the model PT100 7150/E, the machine model, and a photo of the old sensor with your enquiry. That lets us confirm the match before you order.
What the specification fixes, and what it leaves to the machine:
| Parameter | Specification |
| Model | 4-008-40-0054 4008400054 |
| Brand | Shunhongyu |
| Features | Durable And Precise |
| Part Number | 4-008-40-0054 4008400054 |
| Application | Homag Edgebander Glue Pot Accessories |
| Resistance Thermometer Type | PT100 |
| Note | SHUNHONGYU Supplies Various Woodworking Machine Parts, Contact Us Now! |
What changes on the shop floor once the unit is in place:
Match the part number and model on the old sensor to 4-008-40-0054 or 4008400054 and PT100 7150/E. Also compare the thread and probe length before ordering.
It means the PT100 element is rated to measure across that range. The glue pot operates within that window, so the sensor can cover the temperature point.
It is a PT100 resistance thermometer, model PT100 7150/E. The sensing element is platinum, not a thermocouple junction.
The controller loses valid temperature feedback, so the glue pot may drift, fault out, or fail to reach setpoint. Replacing the sensor restores the signal.
Yes, if you match the thread and probe length to the old unit. Check the seat in the glue pot and confirm the part number before installation.
Yes. SHUNHONGYU supplies various woodworking machine parts. Send your part number and machine model with your enquiry.
Send the part number 4-008-40-0054, the model PT100 7150/E, your machine model, and a photo of the old sensor. That helps confirm the match.
Yes, 4008400054 and 4-008-40-0054 refer to the same sensor. Use either number when checking or ordering.
Send your inquiry directly to us